DeLonghi PAC N130HPE Air Conditioner User Manual


 
Troubleshooting
NOTE:
NEVEETRANSPORTORTURNTHEAPPLIANCEUPSIDEDOWNORONITSSIDE.IFTHiSOCCURS,WAIT6HOURSBEFORE
TURNINGTHEAPPLIANCEON,24 HOURSIS EECOMMENDEB(Aftertheunit hasbeenonitsside,oil needsto returntothe
compressorto ensureproperfunction.Withoutallowingtheunit thistime (6-24hours)Theunitmayfunctionforonlyashorttime,
andthenthecompressorwill breakdown fromlackofoiL)
PROBLEM
Theair
conditioningunit doesnot start.
Theair
conditioning unit works for a short
time only.
CAUSE REMEDY
Noelectricity.
It isnotpluggedintotheoutlet.
Thesafetydeviceofthe plughas
tripped.
Theairexhausthosehasa constric-
tion.
Theairexhausthoseisblocked.
Wait.
Plugintotheoutlet.
Resetthe safetydevice,ifproblem
persistscontactourtoll free
customerservice.
Positionthe exhausthosecorrectly.
Checktherearenoobstacles.
Obstructingairdischarge.
Eliminatethe tight bends.Therearetight bendsinthe air
exhausthose.
Theair Windowopen. closethewindow.
conditioner works, but doesnot Theexhausthoseisdetached, connectthe exhausthose.
cool the room. Airfiltersclogged, cleanorreplacethe filter.
Particularodour inthe room air purifyingfiltersclogged cleanorreplacethe filters.
Theair conditioner doesnot the safetydevicehastripped waitfor threeminutes.
operatefor about 3 minutes after
turning it on
Thealarm light Qcomeson the tankinsidetheapplianceisfull. emptythe tank(see"Endofseason
operations)on page10).
SELF-DIAGNOSIS
Theappliancehasaselfdiagnosissystemtoidentifya numberofmalfunctions.Errormessagesaredisplayedon theappliance
display.
IF... IS DISPLAYED, IF... IS DISPLAYED, IF... IS DISPLAYED,
"LowTernperature"
...MEANS:roomtemperatureistoolow
"HighTemperature"
...MEANS:roomtemperatureistoohigh
"ProbeFailure"
(sensordamaged)
...MEANS:contactyourlocalcustomerservice
11
Downloaded from www.Manualslib.com manuals search engine