14
TROUBLESHOOTING
SYMPTOMS
The Pinguino does not
function:
The Pinguino does not
function
- function fault warning
light is on (pag. 10 -
“Alarm” light)
After correcting problem,
press reset button (see
pag. 5)
The Pinguino produces
cold air but room does
not maintain comfortable
temperature:
CAUSE
SOLUTION
- power failure
- plug is disconnected
- ON/OFF switch is off
- Timer key is in STOP position
- insert plug
- switch on
- release the TIMER key
- exhaust hose blocked
- exhaust hose twisted or bent
- ventilation holes on the rear of
the machine or front louvers
blocked
- Check for obstruction of air
outlet vent
- eliminate irregularities
- remove obstacles to allow
proper airflow
- window open
- air exhaust hose has become
disconnected
- thermostat set too low
- air filter blocked
- water tank empty
- close window
- re-insert exhaust hose
- set thermostat to higher
number
- clean filter
- refill it
SERVICING
In case of malfunction turn off and disconnect the Pinguino from power outlet and contact our Service
Centre for qualified assistance, toll-free number 1-800-322-3848 or 1 - 877-235-1052 in America or
no. (905) 238-1313 for Canada.
PERIODIC MAINTENANCE
Calcium deposits may build up on some working parts of Pinguino during operation. Monthly cleaning
(more often in hard water areas) should be done per the following procedure:
- Unplug the machine. Remove the water tank. Run the air-conditioner until water level indicator
light turns on.
- Remove drainage tube plug and empty water. Replace drainage tube plug and add one quart of
clean water to the collecting tray.
- Empty contents of one 8-ounce bottle of Descaling Fluid into the collecting tray. Plug in the
machine and operate until water level indicator light goes on. Turn off and unplug machine.
- Drain the remaining liquid and re-plug the drainage tube.
- Refill the tank with clean water and replace in the machine.
- Plug in and turn on the machine. While the air-conditioner is operating, unplug the drainage tube
and drain until the water looks clean. Replace the drainage tube plug.