11
MINIMUM BURNER SETTING ADJUSTMENT
Check whether the flame spreads to all burner ports when the burner is lit with the
gas tap set to the minimum position. If some ports do not light, increase the minimum
gas rate setting.
Check whether the burner remains lit even when the gas tap is turned quickly from
the maximum to the minimum position. If the burner does not remain lit, increase the
minimum gas rate setting.
The procedure for adjusting the minimum gas rate setting is described below.
For taps with adjusting screw inside the shaft (fig. 8):
✓ using a screwdriver max. diameter 3 mm turn the screw inside the tap shaft until
the flame setting is correct.
For taps with adjusting screw on the body (fig. 9):
✓ using a screwdriver turn screw A until the flame setting is correct.
Normally for ULPG, fully tighten the adjustment screw.
LUBRICATING THE GAS TAP
If a gas tap is difficult to turn, disassemble it, clean it carefully with petrol and spread
a little high-temperature-resistant grease on it.
These operations must be performed by an Authorised person/Service agent.
A