20
Figure 16 Figure 17
CORRECT POSITIONING OF THE BURNERS
■ It is very important to check that spreader F and cap C of the burner (see
Figures 16 and 17) are perfectly in place because if they move out of place
serious problems could arise.
■ Make sure that electrode S (Fig. 16) is kept clean so that the sparks always
strike.
■ Model DEGH60 only: make sure that probe “T” (fig. 16) next to each burner
is kept clean to ensure correct operation of the safety valves.
■ Both the probe and ignition plug must be very carefully cleaned.
■ Note: To avoid damage to the electric ignition do not use it when the
burners are not in place.
GAS TAPS
■ Regular lubrication of the gas taps must only be performed by Authorised
person.
■ If the gas taps are not working properly, call our Customer Service Centre to
obtain the nearest Authorised Delonghi Service Agent.
Figure 16
S
T
F
C