Defy Appliances DGS 130 Stove User Manual


 
PAGE 5 OF16
Gas installation
The necessary installation including gas and electrical connections must be carried out by
qualified personnel in accordance with current and local regulations, since an installation
by an unqualified person may constitute a hazard.
The manufacturer declines liability for injury to persons or damage caused due to non
compliance with these provisions.
The accessories shown below are not supplied and must be acquired by the consumer.
LPG cylinder with plastic hose
LPG
Flexible
hose
Regulator
cylinder
This appliance uses LPG ( Liquid petroleum or bottle gas)
This appliance requires an operating pressure of 2.75 kPa at the appliance. A suitable LPG
regulator that complies with the requirements of SANS 1237 must be used.
The manufacturer and the seller do not accept responsibility for any damage due to
incorrect installation or gas connection.
Gas bottles should be located outdoors in a suitable ventilated lock-up.
The connecting hose should not exceed 125 cm in length.
Soak the end of the plastic hose in hot water to soften it and then push the hose end fully over
the hose nozzle. ( see sketch 1 above)
Secure the hose by tightening the hose clamp. ( See sketch 2 above )
In a similar fashion, secure the other end of the hose to the regulator on the gas bottle.
(See sketch 3 above)