Dayton 5S1792 Water Heater User Manual


 
Operating Instructions & Parts Manual
Dayton Portable
Oil-Fired Heaters
®
Form 5S1792
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Unpacking
1. Remove all packing items supplied
with heater for shipment.
2. Remove all items from carton.
3. Check heater for any shipping
damage. If heater is damaged,
promptly inform dealer where you
purchased heater.
2E510F, 2E511F, 3E218F, and 3E219F
Version B - For Reduction G016.J
®
Figure 1 – Models 2E510F and 2E511F Figure 2 – Models 3E218F and 3E219F
Description
Dayton Models 2E510F, 2E511F, 3E218F, and 3E219F are 40,000 to 155,000 Btu/Hr
heaters. These heaters use only Kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels
for combustion and electricity to run the motor. They are primarily intended for
indoor and outdoor temporary heating of well-ventilated buildings under
construction, alteration, or repair. They may be used in agricultural, industrial,
and commercial environments. Products of combustion are vented into the
area being heated.
Printed in U.S.A.
03430
0403/114/VCPVP
®
General Specifications
Model 2E510F Model 2E511F Model 3E218F Model 3E219F
Output Rating 40,000 Btu/Hr 60,000 Btu/Hr 110,000 Btu/Hr 155,000 Btu/Hr
Fuel Kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels
Fuel Tank Capacity 3.0 U.S. Gallons 5.0 U.S. Gallons 9.0 U.S. Gallons 13.5 U.S. Gallons
Fuel Consumption 0.3 U.S. Gallons/Hr 0.44 U.S. Gallons/Hr 0.8 U.S. Gallons/Hr 1.14 U.S. Gallons/Hr
Motor 1725 RPM 1725 RPM 3450 RPM 3450 RPM
Hot Air Output (CFM) 170 180 490 550
Air Pump Pressure 3.0 psi 3.4 psi 5.1 psi 5.9 psi
Shipping Weight 32 Lb 33 Lb 54 Lb 63 Lb
Heater Weight without Fuel 28 Lb 29 Lb 46 Lb 54 Lb