Dayton 3VH34 Electric Heater User Manual


 
Dayton Installation, Operation, Maintenance and Parts Manual
Dayton High Intensity Heaters
®
3E132 thru 3E134, 3E460 thru 3E462,
5VD57 thru 5VD66, 3VH34 thru 3VH37
E
N
G
L
I
S
H
Safety Signs and Labels
It is important to provide warnings to alert individuals to
potential hazards and safety actions. ANSI Z83.19a and the
National Fuel Gas Code require you to post a sign “specifying
the maximum permissible stacking height to maintain the
required clearances from the heater to the combustibles”
near the heaters thermostat or in absence of such
thermostats in a conspicuous location. Signs should state the
hazards for the particular application and be legible to the
building occupants. Consult the factory or a factory
representative for additional information on signage
compliance.
8
Back Panel
Bottom Panel
F/N: LLDR002
Not For Residential Use!
Improper installation, adjustment, alteration,
service or maintenance can cause property damage, injury or death. Read
the installation, operation and maintenance manual thoroughly before
installing or servicing this equipment.
This is not an explosion-proof heater. Where there is the possibility of flammable vapors
or dusts, consult the local fire marshal, fire insurance carrier or other authorities for
approval of the proposed installation. Always maintain minimum ventilation requirements.
This heater must be installed in accordance
with the latest edition of ANSI/NFPA
Standards, state and local codes. These
applications must comply with:
Parking Structures, ANSI/NFPA 88A.
Repair Garages, ANSI/NFPA 88B.
Aircraft Hangars, ANSI/NFPA 409.
Form # LLDCL001-5M-9/06 (MWG)
30,000 BTU/H
3E132, 3E460,
5VD61, 5VD62
!
CLEARANCE TO COMBUSTIBLES
FIRE HAZARD. Always maintain published clearance to combustibles.
In locations used for the storage of combustible materials, signs must be
posted. Consult manual for additional guidelines.
MODEL NO.
SIDE BACK
TOP BELOW
DANGER
60,000 BTU/H
3E133, 3E461,
5VD63, 5VD64
90,000 BTU/H
3E134, 3E462,
5VD65, 5VD66
130,000 BTU/H
160,000 BTU/H
30” 18” 28” 72”
32” 18” 40” 72”
48” 30” 42” 98”
48” 30” 52” 120”
50” 32” 60” 132”
Do not mount heater horizontally.
20°-35°
Below
Back
Top
Side
Side
MOUNT LEVEL
Angle 20°-35°
DO NOT MOUNT HORIZONTALLY
INSTALLER
CAUTION
Mount heater with
this end down
Mount with
control end
down.
SIDE VIEW
FRONT VIEW
Ignitor in
lower-right
corner.
Da
yton
F/N: LLDCL002
Manifold Pressure
Max. Inlet Pressure
Min. Inlet Pressure for
Purpose of Input Adjustment
Min. Mounting Angle
Max. Mounting Angle
W.C.P.
W.C.P.
W.C.P.
7.0in.
14.0in.
6.0in.
20 DEGREES
35 DEGREES
120V
0.1
0.1
C1
VOLTS AC 60Hz
AMPS - Starting
AMPS - Running
Heater Type:
DESIGN COMPLIES WITH:
ANS Z83.19-2001-GAS FIRED HIGH INTENSITY INFRA-RED HTR.
Serial No. 0603DETR 21400 0001
MANUFACTURED FOR:
DAYTON ELECTRIC MFG. CO.
NILES, IL 60714 U.S.A.
3E133E
MODEL NO.
60,000
INPUT BTU/H
NAT GAS
FOR USE WITH
DAYTON INFRA-RED RADIANT HEATER
FOR INDOOR INSTALLATION ONLY
SAMPLE
Rating Plate
Safety warning labels must be maintained on the
infra-red heater. Illustrations of the safety labels,
and their locations, are pictured below.
Maintain Clearances to Combustibles to Prevent the Risk of Fire.
Clearances to combustibles must be maintained in order to prevent
the ignition of combustible materials. In locations used for the
storage of combustible materials, signs must be posted to specify the
maximum permissible stacking height to maintain the required
clearances from the heater to the combustibles. Signs must either be
posted adjacent to the heater thermostats or in the absence of such
thermostats in a conspicuous location. Clearances are provided on
the heater’s safety labels and in the heater’s Installation & Operation
Manual. Refer to applicable ANSI or NFPA-54 Standards or local codes
for further information. Post this tag adjacent to the heater’s
thermostat or controls before operating the heater.
WARNING
AVOID SERIOUS INJURY, DEATH OR PROPERTY DAMAGE.
!
INSTALLER. READ AND POST THIS NOTICE.
F/N: LL01 - Clearance Safety Tag
(Affix adjacent to heater’s thermostat)