Dansons Group FPP, IPP Indoor Fireplace User Manual


 
Can
adian Comfort Industries V04 19 PELPRO OWNERS MANUAL
Copyright 2004
www.pelprostoves.com Dansons Group Inc.
FIREPLACE INSERT INSTALLATION CONTINUED
When installing into a masonry chimney, it is recommended that the exhaust vent be extended to the top of
the chimney as shown to the lower right. However, if the vent pipe does not extend to the top of the
chimney, the pipe must extend a minimum of 18” above the damper.
You must seal the damper area with a steel plate when using the direct connection method.
The Vent Pipe Must Extend Above The Damper into the first tile of the flue liner (Figure 25) in the USA and
to the top of the chimney CANADA (Figure 26). The chimney must not be corroded or damaged in any way
for this type of installation to be permitted. A direct vent may be made through the chimney structure if local
codes permit.
Figure 25 Figure 26
Metal
Sealing Plate
18” min.
length
18”18”18”
8”
Note: This installation allowed in Canadanot
DIRECT CONNECTIO
N
6”
Liner Support
Deluxe Cap
Optional
Metal Plate
6”
18”
8”
FULL CHIMNEY RELINE
Note: This installation recommended
for all chimney installations!
is