PECIFICATIONS
PECIFICATIONS
HEATING SPECIFICATIONS
DIMENSIONS
ELECTRICAL SPECIFICATIONS
Electrical Rating = 115 Volts 60 HZ 2.0 Amps
Watts (operational) = 175 (approximately)
Watts (optional igniter) = 475 (approximately)
A voltage surge protector or ground fault outlet is required for this unit. The warranty on the circuit
board will be voided if surge protection is not installed before operating this unit.
If power outages or disturbances are a concern, you may wish to purchase a gas powered generator,
solar or battery back-up system. Ensure that it is a “Positive” sign wave and a minimum 1000 watts
continual.
EPA COMPLIANCE
This heater is exempt from EPA Phase II requirements, but has been tested for emissions using EPA test
methods by Warnock Hersey , US. Pellet appliances that are designed with the combustion air supply ex-
ceeding 35:1 (by ratio) are exempt from EPA regulations.
PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE.
¹ Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and
the outside temperature. Fuel size, quality, density and moisture level will also have an effect.
¹¹ Pellet size may affect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as
much as 20%. Use PFI listed fuel for best results.
Approx. Heating capacity (sq. feet) * 800 – 2,000
Approx. Fuel burn rate per hour ** 1.5 – 5 lbs
Hopper Capacity - Home 120 120 lbs Approx. Burn time at lowest setting 90 hrs
Hopper Capacity – Home 300 300 lbs. Approx. Burn time at lowest setting 200 hrs
+
+
8 1/4”
8 3/4”
14 1/4”
3 3/4”
26”
24”
46 1/2”
8 3/4”
24”
31 1/2”
Glow Boy Shop 300 /
or Home 300
Glow Boy Shop 120 /
or Home 120
Common for
all models
Weight
272 lbs.
225 lbs.
Exhaust
Air Inlet
Glow Boy Shop 300 /
or Home 300
Glow Boy Shop 120 /
or Home 120
+
+
8 1/4”
8 3/4”
14 1/4”
3 3/4”
26”
Exhaust
2” Air Inlet
Glow Boy Home & Shop Heater www.glowboystoves.com 8