Window / Patio Door Kit Installation
(Air Conditioning Mode ONLY)
Your window kit has been designed to fit most
standard “vertical” / “horizontal” windows and patio
doors up to a maximum height of 80”. For vertical
window and/or patio door applications, lock
positions are provided in each slider sction. Wing
nuts are also provided to secure the sections
togethor (see Fig. 5a).
Rain Hood Assembly
1) Fold both sides of
the Rain Hood 90
°
as so
the flanges are facing
outward. Fig 1
2) Slide the Rain Hood
flanges onto the edges of
the slider kit until it is
lined up with the intake
vent (shown in Fig 2). Once the mounting holes on
the slider, as well as the Rain Hood are aligned,
secure the Rain Hood to the slider with the four
mounting screws provided.
IMPORTANT:
• For horizontal window kit applications refer to
figure 3a for correct Rain Hood insert positioning.
• For vertical window kit applications (including
patio) refer to figure 4a for correct Rain Hood insert
positioning.
1) Select a suitable location,making sure you have
access to an electrical outlet.
2) Install both flexible hoses to the rear side of the
unit. Both hoses are identical and can be installed
into either opening. Insert the hose collar with the 2
lock tabs into the 2 slots on the top of each
opening and twist to lock into position.
3) Install the adjustable Window/Patio Door Slider
Kit as required. Fig’s. 3, 4, 5.
4) Install the window exhaust adapters into the
openings in the slider section, making sure the
window slider sections are secure.
Important:: Ensure the exhaust adapter labeled “air
intake” is installed on the hose that is connected to
the air intake opening on the back of the unit.
Horizontal Window
Window Slider Kit
Minimum: 28" (71.1 cm)
Maximum: 48
3
/8" (123 cm)
Vertical
Window
Fig. 3
Fig.4
Patio
Door
Patio Door Kit
Minimum: 28" (71.1 cm)
Maximum: 80" (203 cm)
Fig. 5
Fig.
Please Note: In a vertical application, the
exhaust hose MUST be positioned above
the
intake hose in the window slider. See Fig 5.
This will avoid having the exhaust heat go
through the intake and back into the unit.
6
Window Slider Kit
Minimum: 28" (71.1 cm)
Maximum: 48
3
/
8" (123 cm)
Fig. 3a
A
B
Fig. 2
Fig. 1
Rain hood inserts are
installed in “A” and “B”
postions with vent open-
ing facing down (C)
C
Fig.4a
A
B
C
Intake hose
adapter
Rain
Hood
Slider kit
Rain hood inserts are
installed in “A” and “C”
positions with vent open-
ing facing down (B)
Rain Hood is to be installed only over air intake vent
Air exhaust
Air intake
Plug the unit into a 115 V / 60 Hz grounded
electrical outlet.