Danby DDR2509EE Dehumidifier User Manual


 
10
CARE AND MAINTENANCE
CLEANING
CAUTION: Before attempting to clean and/or service this unit, always
disconnect the power supply cord from the electrical supply outlet.
1) DO NOT use gasoline, benezene, paint thinner, or any other chemicals to clean this unit, as
these substances will damage/deform both plastic components and luster finish.
2) Never attempt to clean the unit by pouring water directly over any of the surface areas, as
this will cause deterioration of electrical components and wiring insulation.
3) Use only a mild dish washing detergent, lukewarm water, and a soft cloth to wipe the
exterior surface of the unit and dry thoroughly.
STORAGE
When the dehumidifer is not being used for long time periods, please follow
these instructions:
1) Disconnect the power cord from the power supply.
2) Empty the water tank and wipe (clean) thoroughly.
3) Clean air filter thoroughly.
4) Re-package the unit in the original carton.
5) Store the unit upright in a dry location.
TROUBLESHOOTING GUIDE
Occasionally, you may encounter some problems that are of a minor nature and a service call
may not be necessary. Use this troubleshooting guide to identify possible problems you may be
experiencing. If the unit continues to operate improperly, call your local Danby Service Depot or
1-800-26- (1-800-263-2629)
PROBLEM POSSIBLE CAUSE
Unit will not operate
Dehumidifying capacity (moisture
removal) low.
Relative Humidity setting not
reached after long period of
operation
• Check power cord connection
• Check electrical outlet for blown fuse
• Check if water tank is full (if yes, empty)
• Check water tank is properly installed
• Air filter is dirty and/or blocked
• Ambient (room) temperature too low (below
5°C/ 41°F)
• Poor air flow circulation/obstruction of front
grill
• Relative humidity in surrounding environment
very low
• Check all doors and windows are closed
• Area/room is too large for the capacity of the
dehumidifier