Dacor MH30 Stove User Manual


 
19
Turn off power to the hood electrical circuit at the circuit 1.
breaker or fuse box.
Feed the wiring through the wiring access holes in the 2.
hood. Connect the wiring to the terminal block inside
the hood as shown.
Connect the hood wiring to an electrical junction box 3.
on a dedicated circuit. See page 6 for specifications.
Connect it according to the wiring diagram below or on
the following page.
L1
N1
Gnd
Not used
Installation Instructions
To junction
box
Hood Power
Terminals
Ground (Green)
Neutral (White)
Hot (Black)
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
3 Wire Connection to Junction Box
UL/CSA approved
NEMA strain relief
To house circuit breaker
panel or fuse box
To range hood
Junction Box
Wire Nut,
3 places
Final Electrical Installation
WARNING
To avoid electric shock or fire hazard, prior to connecting the electrical wiring to the hood, make sure that power to •
the hood power supply line is turned off at the fuse box or circuit breaker panel.
Improper connection of the hood electrical wiring may create an electric shock or fire hazard and may result in dam-•
age to the hood’s electrical system. See page 6 for specifications.
Do not ground the hood to the neutral (white) power supply wire. Connect the hood ground wire to a separate, prop-•
erly grounded wire installed by a licensed electrician.
Make sure all wire used is capable of handling the total connected load. See page 3.•