Coway CHP-06ER/L Water System User Manual


 
26 27
CLEANING METHOD
Gutter
1
Separating the gutter
It is easily disassembled by holding the
gutter after removing the gutter cover.
2
Installing the gutter
After adhering the gutter closely to the
front side of the product and slightly raise
the gutter cover.
Cleaning Method Filter Replacement and Daily Check
/
Installation and Cleaning
Filter Replacement
FILTER REPLACEMENT
AND DAILY CHECK
Filter
The vitality of product is the filter. The fraudulent filters or
missing time for filter change may degrade the
performance and so interrupt the filtration.
If the filter is not regularly replaced, it may degrade the water quality from the product. The filter
change cycle may vary within the range of expected replacement cycle depending on the feed
water quality.
The period for the filter exchange is made based on 10 use in a day for house use (4 people
based) and 20 use for business.
Estimated Time of Filter Replacement
About Estimated Time of Filter Replacement
The filter change cycle described above is not the filter quality
warranty period but the expected cycle that the filter shows its
original performance. (based on the tap water.)
The filter change cycle may be reduced for the areas with poor
water quality or more applications.
Part No.
Names of Filter
Usable Period
Neo-sense filter
WJNF14
WJMF14-75
WJMF14S-50
WJCFC14-POST
WJCC-02
Membrane filter(CHP-06ER)
Membrane filter(CHP-06EL)
Fine post-carbon filter
Ceramic filter
18
months
12
months
6 months
24 months
24 months
The product water should be tested every 6 months to ensure
that the contaminants are being reduced effectively.
Please contact your local dealer or Coway to initiate this service.
This reverse osmosis system contains a replacement component critical to the efficiency of the
system. Replacement of the reverse osmosis component should be one with identical
specifications, as defined by the manufacturer, to assure the same efficiency and contaminant
reduction performance.
This reverse osmosis system contains a replacement treatment component critical for the
effective reduction of total dissolved solids, and that the product water shall be tested periodically
to verify that the system is performing properly.