Cooper Lighting MD6xT4 Indoor Furnishings User Manual


 
704530 Rev. A - 4 - Customer First Center · 1121 Highway 74 South · Peachtree City, GA 30269
Port folio
®
Lamping Information
The electronic ballast has a very important shutdown timing feature that turns off the ballast output after time
periods ranging from 2 minutes up to 30 minutes if a lamp does not start or operate properly or if the fixture wiring
is improper. For proper system diagnosis and at lamp replacement time, the INPUT POWER TO THE BALLAST
MUST BE RESET (turn power off, wait 10 seconds, turn power back on) to start a new lamp.
Take proper care in handling and disposing of the old lamp. Do not touch glass bulb with bare hands.
Lamp contains Mercury. Manage in accordance with disposal laws. See www.lamprecycle.org or 1-866-666-
6850.
Main Lamp
Ceramic Metal Halide Lamp
MD6xT6G12 Housings
G12 socket for one 20W, 39W, 70W or 150W lamp. Generic lamp
designations (lamp by others):
M156/E (20W)
M130/E (39W)
M98/E, M139/E (70W)
M102/E, M142/E (150W)
MD6xT4G85 Housings
G8.5 socket for one 20W, 39W, or 70W lamp. Generic lamp
designations (lamp by others):
M156/E (20W)
M130/E (39W)
M98/E, M139/E (70W)
MD6xT4G65 Housings
GU6.5 socket for one 20W or 39W lamp. Generic lamp designations
(lamp by others):
M156/E (20W)
M130/E (39W)
Quartz Lamp
Quartz Restrike Lamp
The Quartz lamp is a 100W, 120V, T4 Bulb with a “DC Bayonet” base.
This housing may be re-lamped either from below or above the ceiling.
Allow sufficient time for the lamp to cool.