Cooper Lighting Indoor Lighting Indoor Furnishings User Manual


 
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-659 ADW051683
Epic/Pole Mounted
Fixtures
Sheet 4 of 4
10/18/05 IMI-659
INSTALLATION INSTRUCTIONS
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
TM
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
Vertically lamped
1. Loosen and remove ring retaining screws globe retaining
ring and globe. Components are not tethered.
See Figure 5.
2. Remove two screws on ballast cover followed by ballast
cover. See Figure 6.
3. Unplug optic quick-disconnect.
4. Unplug service quick-disconnect.
5. Loosen the two screws holding the power pack to the
fixture housing. See Figure 7.
6. Holding the power pack by the handle, rotate the power
pack until free and lower.
7. Holding replacement power pack by handle, raise onto
screw heads and rotate.
8. Tighten the two screws while holding power pack in
position.
9. Plug together the service quick-disconnect.
10. Plug together the optic quick-disconnect.
11. Resecure the ballast cover with the two screws.
12. Reinstall ring retaining screws securing globe retaining ring
and globe. In the case of type 3 refractive glass globe, use
the mark on globe bottom for orientation.
Keyhole Slot
Fig. 6
Rectangular Washer
Thumbscrew
Reflector
Removal
Ballast Cover
Screws
Optic
Quick-
Disconnect
Fig. 7a
Starter
Fig. 7b
Handle
Fuse
Service
Quick-Disconnect
Screws
Fig. 8
Power Pack Removal