Cooper Lighting IMI-682 Indoor Furnishings User Manual


 
2. Remove the plug-in starter from the receptacle and replace.
FIG. 6
3. Assure that the thumbscrews on the powertray and both latches
on the door are fastened securely.
OPTIC DISTRIBUTION AND ORIENTATION
The Talon Large fixture is offered with some optics that have
directional distributions. For aiming purposes, the Talon Large was
designed with the flexibility to allow each of its optics to be rotated
to any of four (4) positions, located at 90° increments. There are
two (2) mounting configurations that are used to mount all of the
Talon Large optics. The horizontally-lamped optics (as well as the
Type 4 vertical optic) use the horizontal optics adapter. All vertically
lamped optics use the vertical mount adapter.
1. Vertical Optics: Open the door and remove the lamp. Use a
screwdriver to slightly loosen (do not remove) the four (4) screws
as shown in FIG. 7. The optic has four (4) keyhole details that
allow it to release by turning the reflector clockwise a few
degrees allowing the optic to be removed. Reposition the optic
and tighten the screws securely.
2. Horizontal Optics: (this also covers the Type 4 vertical optic).
Open the door and remove the lamp. Use a screwdriver to
remove the four (4) screws as shown in FIG. 8. Reposition the
optic and reinsert the screws securely.
These instructions do not claim to cover all details or variations in
the equipment, procedure, or process described, nor to provide
directions for meeting every possible contingency during
installation, operation or maintenance. When additional information
is desired to satisfy a problem not covered sufficiently for user's
purpose, please contact your nearest representative.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency
during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest
representative.
Talon Large
Sheet 3 of 3
11/29/07 IMI-682
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
WARNING: Risk of Fire/Electric Shock. If not qualified, consult an electrician.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.
WARNING: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components
to their recommended torque values.
WARNING: Risk of Fire/Electrical Shock. Upside down installation can result in overheating or accumulation of water in fixture.
Install right side up.
NOTE: Specifications and dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH071365
FIG. 8
Remove Optic, Rotate
To Desired Position
And Fasten Into Place
FIG. 6
Plug-In Starter
Thumbscrews
FIG. 7
Remove Optic, Rotate
To Desired Position
And Fasten Into Place