4. Attach Housing to Mast Arm Adapter -
Remove the WIREWAY PLUG from the
HOUSING. Move the fixture leads aside so
the THREADED RODS may be accessed
through the fixture HOUSING.
See Figure 4a.
Attach the MAST ARM ADAPTER to the
HOUSING by inserting the threaded studs
into the fixture HOUSING. Feed the fixture
wires through the MAST ARM ADAPTER.
Slide the HOUSING over the threaded
rods and secure it with the PLAIN
WASHERS, LOCK WASHERS, and HEX
NUTS. See Figure 4b.
Torque HEX NUTS as follows:
Medium Icon (ICM) - 450 in-lbs.,
Small Icon (ICS) - 130 in-lbs.
NOTE: It may be helpful to use a deep
socket when installing the HEX NUTS.
Re-install the WIREWAY PLUG into the
wireway in the HOUSING.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-606 AVU040954
Mast Arm Adapter
Sheet 3 of 5
5/26/04 IMI-606
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
RETAIN FOR FUTURE REFERENCE.
TM
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
WARNING
Risk of Personal Injury
Fixture may become damaged and/or
unstable if not installed properly
Tighten all fixture components to their
recommended torque values
Wireway Plug
Fig. 4a
Fig. 4b