CFM UVLXM24RN Indoor Fireplace User Manual


 
13
20009012
4. Push in gas control knob slightly and turn
clockwise to "OFF". Do not force.
5. Close control access panel.
1. STOP! Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. For MN/MP/TN/TP appliances ONLY, go
on to Step 4. For RN/RP appliances turn
the On/Off switch to “OFF” position or set
thermostat to lowest level.
4. Open control access panel.
5. Push in gas control knob slightly and turn
clockwise to "OFF".
10. Push the control knob all the way in and
hold. Immediately light the pilot by repeatedly
depressing the piezo spark ignitor until a flame
appears. Continue to hold the control knob in
for about one (1) minute after the pilot is lit.
Release knob and it will pop back up. Pilot
should remain lit. If it goes out, repeat steps 5
through 8.
FOR YOUR SAFETY READ BEFORE LIGHTING
If you cannot reach your gas supplier, call
the Fire Department
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob
will not push in or turn by hand, do not try to
repair it, call a qualified service technician.
Applying force or any attempted repair may
result in a fire or explosion.
D. Do not use this fireplace if any part has been
under water. Immediately call a qualified
service technician to inspect the heater and
to replace any part of the control system and
any gas control which has been under water.
A. This heater has a pilot which must be lit
manually. When lighting the pilot follow
these instructions exactly.
B. BEFORE LIGHTING smell all around the
heater area for gas. Be sure to smell next
to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any fireplace
Do not touch any electric switch
Do not use any phone in your building
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
To Turn Off Gas To Heater
Lighting and Operating Instructions
1. Turn the On/Off switch to Off position or set
the thermostat to lowest setting.
2. Turn off all electric power to the fireplace if
service is to be performed.
3. Open control access panel.
Lighting Instructions
6. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information above. If you do not
smell gas, go to the next step.
7. Remove glass door before lighting pilot.
(See Glass Frame Removal section).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise
to "PILOT".
If knob does not pop up when released,
stop and immediately call your service techni-
cian or gas supplier.
If after several tries, the pilot will not stay
lit, turn the gas control knob to "OFF" and call
your service technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. For RN/RP appliances turn the On/Off switch
to “ON” position or set thermostat to desired
setting.
14. Turn on all electrical power to the fireplace.
WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
Euro SIT SIT NOVA
Honeywell
PILOT
ON
OFF
ON
P
I
L
O
T
O
F
F
O
F
F
FP1067
lighting instruction
knobs
3/9/01 djt
5
4
3
2
1
O
F
F
P
i
l
o
t
3/8" - 1/2"
FP1068
Lighting instructions
Pilots