Continental CDIZC - N Indoor Fireplace User Manual


 
7
W415-0224 / D / 01.15.04
To adjust the trim: If the mitre is out of alignment, open
each side and loosen the two screws at either side trim
hinge. Slide the trim up or down to adjust and re-tighten
screws. There is also a very slight in/out adjustment that
can be made.
Note: Since the side panels open and close, to access
the controls, a gap is necessary at the mitre joint.
The top trim piece has an adjustable securing bracket
which enables the trim to be secured to the firebox shell.
In order to close off the fireplace opening or if the opening
is larger than the 3- or 4-sided aluminium extrusion trim
kits, it is recommended to reduce the opening using a non-
combustible material such as ceramic tile, marble, etc or
the GIZBP6-3 or GIZBP6-4 backer plate kits. The outside
edge of the backer plate is finished off with gold trim in-
cluded in each kit. A deluxe flashing kit complete with mar-
quis trim may also be used to complete the installation.
These flashing and trim combinations are available in 6
and 9 inch widths as well as many finishes to accent any
room decor. Mounting brackets, GIZBRKT, are required to
install the deluxe flashing. Detailed installation instructions
are included with each kit.
If this unit is being installed into an existing wood burning,
zero clearance fireplace, then be aware of this precaution:
Any circulation air opening may be covered (with non-
combustible material) but not sealed!
The insert can be equipped
with either a 3- or 4-sided
trim kit to finish off the fire-
place opening. Slide the trim
assembly over the keyholes
(2 per side) and drop into
place. If installing the op-
tional 3- or 4-sided backer
plate (GIZBP6-3 or GIZBP6-
4), it must be hung prior to
the trim kit installation us-
ing the same keyholes.
FIGURE 8
FIRE VIEWING DOOR
FIGURE 11
FIGURE 6
For ease of accessibility, an optional remote wall switch
or millivolt thermostat may be installed in a convenient
location. Route 2-strand solid core millivolt wire from
the gas fireplace insert to the wall switch / millivolt ther-
mostat. The recommended maximum lead length de-
pends on the wire size:
WIRE SIZE MAX. LENGTH
14gauge 100 feet
16gauge 60 feet
18gauge 40 feet
Do not connect either the wall switch, thermo-
stat or gas valve to electricity (110 VOLTS).
The insert may now be
pushed into its final posi-
tion inside the wood-burn-
ing fireplace. Secure the in-
sert to the fireplace using
perforated strapping at-
tached to the two securing
holes on either side of the
unit as shown. We recom-
mend that the trim be in-
stalled before the unit is
placed into its final position.
SECURING
HOLES
FIGURE 7
FIGURE 9
VALVE
CONTROL
DOOR
Install suitable supply piping connection to the
3
/
8
" flex
connector supplied (as per local gas codes).
FIGURE 10
LOOSEN
SCREWS
SLIDE TO
ADJUST
WALL SWITCH / THERMOSTAT GAS INSTALLATION
FINISHING
ALUMINIUM EXTRUSION TRIM KIT
INSTALLATION