Desa Tech RFP28TC Indoor Fireplace User Manual


 
20
103509
VENT-FREE RADIANT FLAME
®
HEATER
SPECIFICATIONS
BTU (Variable) 14,000/28,000
Type Gas Propane/LP Only
Ignition Piezo
Pressure Regulator Setting 8" W.C.
Inlet Gas Pressure (in. of water) *
Maximum 14"
Minimum 11"
Dimensions, Inches (H x W x D)**
Heater 23.75 x 25.9 x 8.5
Carton 26 x 27.75 x 10.25
Weight (pounds)
Heater 29
Shipping 35
*For purposes of input adjustment
**Measurement includes knobs and hood
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burner will have delayed ignition
heater will not produce specified heat
propane/LP gas supply may be low
When Gas Quality Is Bad
pilot will not stay lit
burner will produce flames and soot
heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.
CLEANING AND
MAINTENANCE
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air,
or small, soft bristled brush to clean.
CABINET
Air Passageways
Use a vacuum cleaner or pressurized air
to clean.
Exterior
Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, etc.
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or troubleshooting.
If so, contact DESA International’s Techni-
cal Service Department at 1-800-323-5190.