LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use
the latest edition of the National Fuel Gas Code ANSI Z223, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Figure 1 - Vent-Free Natural Gas Heater (30,000 Btu/Hr Model Shown)
Ignitor Button Control Knob
Heater
Cabinet
Front
Panel
Glass
Panel
Grill
Guard
UNPACKING
1. Remove heater from carton.
2. Remove all protective packaging applied to heater for shipment.
3. Check heater for any shipping damage. If heater is damaged, promptly inform
dealer where you bought heater.
PRODUCT
FEATURES
Safety Device
This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The
ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off
the heater if there is not enough fresh air.
Piezo Ignition System
This heater has a piezo ignitor. This system requires no matches, batteries, or other
sources to light heater.
Thermostatic Heat Control
Thermostat models have a thermostat sensing bulb and a control valve. This results in
the greatest heater comfort. This can also result in lower gas bills.