Desa Tech CGD3924PT Indoor Fireplace User Manual


 
OPTIONAL
POSITIONING
OF
THERMOSTAT
SENSING BULB
For Masonry and
Factory-built
Metal Fireplace
ICGd04
If your log set cycles to pilot, but the room temperature drops to a lower than
ideal comfort level before the log set comes back on, you maywant to
reposition the thermostat sensing bulb.
The thermostat sensing bulb is located near the gas valve assembly on the mounting
bracket. This location allows the thermostat to keep the room temperature at an ideal
comfort level for most fireplace applications. For positioning the thermostat sensing bulb
elsewhere, an adhesive-backed mounting clip has been provided.
Tools needed: 1/4" hex driver or socket
l. Remove logs. Locate the gas valve assembly and thermostat sensing bulb (see Figure 27).
Gas Valve
Assembly
Mounting Thermostat
Bracket Sensing Bulb
Figure 27- Location of Gas Valve Assembly and Thermostat Sensing Bulb
2. The adhesive-backed mounting clip (see Figure 28) is attached to the thermostat sensing
bulb. Remove the adhesive-backed mounting clip.
Figure28 - Adhesive-backed Mounting Clip
3, With 1/4" hex driver orsocket, loosen the thermostat screw. Carefully slide the thermo-
stat sensing bulb out of the retaining clamp (see Figure 29).
Note: Do not remove the screw. Make sure you tighten the screw after removing the
thermostat sensing bulb.
iMPORTANT: Do not force or bend the thermostat sensing bulb or capillary,
Screw
Retaining Claml:
Sensing Bulb
Figure 29 - Removing Thermostat Sensing Bulb
4. The thermostat sensing bulb may be located to the lower fight front sid_ of fireplace.
Determine location of sensing bulb, but do not mount sensing bulb until step 5. If you
have a masonry fireplace, see Figure 30 on page 30 for location. Continued I