Electrical Specifications
Voltage 120V ac, 60 Hz
Total Amps 7.9 Amps
Total Watts 1050W
Heater Rating 2 x 500W
Illumination 2 x 20W Low Energy Bulb
Electrical Connection
A 15 amp, 120 Volt, 60 Hz circuit with a properly
grounded outlet is required. Preferably, the fireplace
will be on a dedicated circuit as other appliances on the
same circuit may cause the circuit breaker to trip or the
fuse to blow when the heater is in operation. The unit
comes standard with a 6 ft. (1.8 m) long three wire cord,
exiting the left side of the fireplace. Plan the installa-
tion to avoid the use of an extension cord. Extension
cords are for temporary use only. If an extension cord
must be used, it must be UL/CSA certified, rated at 15A
(1875W), 125V maximum with 14 AWG minimum and
constructed of two current carrying conductors with
ground. A heavy duty extension cord with the shortest
length possible for the connection is recommended and
must not be longer than 50 ft. (15.2 m). Do not coil or
cover the extension cord.
place until it has first been inspected if any portion
of it has been exposed to water. Always utilize a
qualified service technician to inspect the fireplace
and to replace any electrical system components
that may have been damaged by water.
Grounding Instructions
This heater is for use on 120 volts. The cord has a plug
as shown at A in Figure 1. An adapter as shown at C
is available for connecting three-blade grounding-type
plugs to two-slot receptacles. The green grounding lug
extending from the adapter must be connected to a per-
manent ground such as a properly grounded outlet box.
The adapter should not be used if a three-slot grounded
receptacle is available.
A
B
C


Grounding Pin
Grounding Means
Adapter
Cover of
Grounded
Outlet Box
Metal Screw
FP1636
Fig. 1 Grounding methods.
35” (910 mm)
24
(615 mm )
9
(250 mm)
5
(145 mm)
36”
(914 mm)
9472
Inspire specs
8/06
[Heater Main Body Width 32” (832 mm)]
23"
(594 mm)
Minimum Shelf Height
(To Heater Main body)
Minimum
From Floor
WARNING
Always confirm that the electrical outlet wiring is
in compliance with all applicable local and national
building codes and electrical code requirements to
avoid the risk of fire or electric shock.
If the fireplace should be exposed to water, imme-
diately turn off the main power supply and remove
the power plug from the outlet. Never use the fire-