CFM Corporation EF28 Indoor Fireplace User Manual


 
10
EF28 Electric Fireplace
10010019



Switch Marking Operation
Master ON/OFF O I On/Off. Depress to I,
this supplies power to the
appliance and places it in
a standby mode.
Fire On/Flame
Effect Only
Low Heat
On/Off
Fire Off
High Heat
On/Off
FP1771
Figure 4
• Heater Operation
The heater is operated by the remote control handset. A master ON/OFF switch is
located behind the lower door of the appliance on the right hand side.
All further operations are controlled by using the remote control handset. (Fig. 4)
1. Ensure the appliance is plugged in and switched on.
2. To turn the fire on, press the fire on/flame effect button.
3. For low heat, ensure the flame effect is on and press the low heat button once. To
turn the low heat off, press the low heat button a second time. The fire will now be
running with flame effect only.
4. For high heat, ensure the flame effect and low heat settings have been switched
on. Press the high heat button. The high heat button will only work if the flame ef-
fect and low heat have already been switched on. To turn high heat off, press the
high heat button a second time. The fire will now be running with low heat.
5. To place the fire in a standby mode at any time, press the fire off button.
Operating Instructions
• Thermal Protection
The fan heater is protected from high heater temperatures due to airflow restrictions
by a temperature limit switch. Some of these restrictions may be due to accumu-
lated dust or debris restricting air flow to the heater. If the limit switch is tripped, cool
instead of warm air is the result. Turn off and unplug power to the unit and allow it to
cool to the touch to investigate the cause of air flow restriction. It may take up to 5
minutes for the heater to cool down before the limit switch resets. Refer to the Main-
tenance section for access to the fan heater.