Cisco Systems SF302-08P Plumbing Product User Manual


 
Cisco 300 Series Managed Switches 3
Do not deploy the device in a location where any of the following
conditions exist:
High Ambient Temperature—Refer to the following table for the high
ambient temperature rating of each switch:
Reduced Air Flow—Both side panels must be unobstructed to prevent
overheating.
Mechanical Overloading—The device should be level, stable, and
secure to prevent it from sliding or shifting out of position.
Circuit Overloading—Adding the device to the power outlet must not
overload that circuit.
Ambient Temperature Ratings
Switch Model High Temperature
SF300-24P 104 degrees Fahrenheit (40 Centigrade)
SF300-24PP 113 degrees Fahrenheit (45 Centigrade)
SF300-24MP 122 degrees Fahrenheit (50 Centigrade)
SF300-48P 104 degrees Fahrenheit (40 Centigrade)
SF300-48PP 122 degrees Fahrenheit (50 Centigrade)
SF302-08P 104 degrees Fahrenheit (40 Centigrade)
SF302-08PP 113 degrees Fahrenheit (45 Centigrade)
SF302-08MP 104 degrees Fahrenheit (40 Centigrade)
SF302-08MPP 113 degrees Fahrenheit (45 Centigrade)
SG300-10P 104 degrees Fahrenheit (40 Centigrade)
SG300-10PP 113 degrees Fahrenheit (45 Centigrade)
SG300-10MP 104 degrees Fahrenheit (40 Centigrade)
SG300-10MPP 113 degrees Fahrenheit (45 Centigrade)
SG300-10SFP 113 degrees Fahrenheit (45 Centigrade)
SG300-28P 122 degrees Fahrenheit (50 Centigrade)
SG300-28PP 113 degrees Fahrenheit (45 Centigrade)
SG300-28MP 122 degrees Fahrenheit (50 Centigrade)
SG300-28SFP 122 degrees Fahrenheit (50 Centigrade)
SG300-52P 113 degrees Fahrenheit (45 Centigrade)
SG300-52MP 113 degrees Fahrenheit (45 Centigrade)