Cisco Systems ONS 15454 SDH Home Security System User Manual


 
15-45
Cisco ONS 15454 SDH Reference Manual, R4.6
April 2008
Chapter 15 Performance Monitoring
15.6.6 TXP_MR_2.5G and TXPP_MR_2.5G Card Performance Monitoring Parameters
15.6.6 TXP_MR_2.5G and TXPP_MR_2.5G Card Performance Monitoring
Parameters
Figure 15-16 on page 15-45 shows the signal types that support near-end and far-end PM parameters.
Figure 15-17 on page 15-46 shows where overhead bytes detected on the ASICs produce performance
monitoring parameters for the TXP_MR_2.5G and TXPP_MR_2.5G cards.
Figure 15-16 Monitored Signal Types for TXP_MR_2.5G and TXPP_MR_2.5G Cards
Note The XX in Figure 15-16 represents all PMs listed in Table 15-50 on page 15-46 through Table 15-55 on
page 15-50 with the given prefix and/or suffix.
Table 15-49 Near-End or Far-End OTN FEC PM Parameters for TXP_MR_10G Cards
Parameter Definition
Bit Errors Corrected The number of bit errors corrected in the dense wavelength division
multiplexing (DWDM) trunk line during the PM time interval.
Uncorrectable Words The number of uncorrectable words detected in the DWDM trunk line
during the PM time interval.
96638
ONS Node
OC-48
100-GHz ITU
Metro DWDM Fiber
Data signal Data signal
ONS Node
OC-48
100-GHz ITU
OTN G.709 (XX-PM or XX-SM)
and OTN FEC (XX) PM
Data PM Data PM
End-to-End Data PM