Protect the extension cords from 8.
sharp objects, excessive heat, and
damp or wet areas.
RECOMMENDED MINIMUM WIRE
GAUGE FOR EXTENSION CORDS*
(120/240 VOLT)
NAMEPLATE
AMPERES
(at full load)
EXTENSION CORD
LENGTH
25’
50’
75’
100’
150’
0 – 2.0 18 18 18 18 16
2.1 – 3.4 18 18 18 16 14
3.5 – 5.0 18 18 16 14 12
5.1 – 7.0 18 16 14 12 12
7.1 – 12.0 18 14 12 10 -
12.1 – 16.0 14 12 10 - -
16.1 – 20.0 12 10 - - -
TABLE A
* Based on limiting the line
voltage drop to ve volts at
150% of the rated amperes.
Symbology
Double Insulated
Canadian Standards Association

V~
Volts Alternating Current
A
Amperes
n
0
xxxx/min.

(RPM)
SPECIFICATIONS
Electrical
Requirements
120 V~ / 60 Hz
1200 Watts
10 Amp Motor

Power Plug: 3 Prong, Grounded
Tank Capacity 13 Gallons
Features
Stainless Steel Tank / Safety
Float / Built-In Storage for Power
Cord & Accessories
Accessories
Filter Cartridge / Foam Filter /
Dust Bag / Telescopic Suction
Tube / Wet & Dry Brush / Crevice
Nozzle / Furniture Brush
UNPACKING
When unpacking, check to make sure
that the item is intact and undamaged. If
any parts are missing or broken, please
call Harbor Freight Tools at the number
shown on the cover of this manual as soon
as possible.
OPERATING INSTRUCTIONS
Read the ENTIRE IMPORTANT
SAFETY INFORMATION section
at the beginning of this manual
including all text under
subheadings therein before set
up or use of this product.
TO PREVENT
SERIOUS
INJURY FROM ACCIDENTAL
OPERATION:
Turn the Power Switch of the
Wet/Dry Vacuum to its “OFF”
position and unplug the
tool from its electrical outlet
before assembling or making
any adjustments to the tool.
WARNING