Chicago Electric 92481 Septic System User Manual


 
SKU 92481 For technical questions, please call 1-800-444-3353. PAGE 9
6. Set the Sump Pump in place, using the accessory Rope (41). Do not raise or
lower the Sump Pump by its Power Cord or by its Discharge Hose.
(See Figure D.)
4. Connect the Discharge Hose to the Connector Plug (39) of the
Sump Pump, using the Discharge Hose Clamp (40) to secure the Discharge
Hose in place. (See Figure D.)
5. Install a Union (not included) or other means of separating the Discharge Hose
just above the floor to facilitate removal of the Sump Pump if necessary.
(See Figure D.)
UNION
(NOT INCLUDED)
DISCHARGE HOSE
(NOT INCLUDED)
POWER CORD/PLUG (1)
FIGURE D
DISCHARGE HOSE CLAMP
(40)
CONNECTOR PLUG
(39)
7. Connect additional Discharge Pipe as needed to direct the discharge to the
desired location. The discharge should be kept as short as possible with
a minimum number of turns. NOTE: The maximum lift of the Pump is 36 feet.
See the Flow Chart (Figure E, next page), indicating gallons pumped per
minute at various lift heights.
8. Plug the Power Cord into its 120 volt, GFCI electrical outlet while making sure to
form a “drip loop” in the Power Cord. Then, turn on the electrical power to the
GFCI electrical outlet. (See Figure B.)