9. The Sump Pump will now start and run continuously until electrical power to the
Pump is shut off.
10. When shutting off power to the Sump Pump, always shut off the electrical
power to the GFCI outlet first. Then, disconnect the Sump Pump’s Power
Plug from the GFCI outlet.
TROUBLESHOOTING
1. WARNING! Always make sure the electrical power to the Sump Pump’s
GFCI electrical outlet is shut off first and then the Pump is unplugged from its
outlet
prior
to performing any maintenance to the unit. This Section is designed
to help identify reasons for operating problems. It is
not
a service guide.
Dismantling the Sump Pump voids warranty. Servicing of the Sump Pump (other
than simple cleaning or unplugging) should be done only by a qualified service
technician.
2. Pump Motor does not run.
A. Line circuit breaker may be off. Have a certified electrician check the fuse or
breaker.
B. Water level in pit may be too low. Add more water to pit.
C. Power Cord may not be making contact in electrical outlet. Check connection.
3. Pump Motor Runs, but does not discharge water.
A. Discharge Hose may be frozen or blocked. Check to see if Discharge Hose
passes through cold areas or is blocked.
B. Vertical lift is beyond Sump Pump’s capability. Maximum lift capability is 36
feet.
FIGURE E
0
15
20
25
30
35
10
20 30
40 50
60 70
GPM
FT
Flow Chart