Error Messages
Message Cause(s) Action(s)
Lamp Startup Fail
The lamp has not started after being struck
· Check lamp
· Check lamp socket and wiring
·
Check ballast and igniter
Temperature Sense
Error
No communication with temperature
sensor
· Check sensor wiring
· Check sensor integrity
· Check control board
Lamp too Hot Low
Power
Ambient temperature higher than 105º C;
lamp in low power for safety
· Check fans
· Check fan wiring
·
Clean vents
Lamp Too Hot Power Off
Ambient temperature higher than 110º C;
lamp off for safety
·
Check fans
· Check fan wiring
· Clean vents
Maintenance Fixture
Fixture Maintenance timer expired
·
Proceed with maintenance and reset timer
Lamp On Over 700 Hour
Lamp change is overdue
·
Change lamp
Memory Initial Fail
Memory chip error
·
Change main board
CPU-B Error
CPU-C Error
CPU-D Error
No communication with auxiliary CPU
· Check sensors wiring and position
· Check stepper motor, belt, and driver board
· Check control boards
Pan Reset Error
Pan Encode Error
Tilt Reset Error
Tilt Encode Error
Moving head failed going to home position
after power up or fixture reset
· Check moving head’s free movement
· Check sensors’ wiring and position
· Check stepper motor, belt, and driver board
· Check the corresponding control board
· Check main control board
Shutter Reset Fail
Dimmer Reset Fail
Color Reset Fail
Cyan Reset Fail
Magenta Reset Fail
Yellow Reset Fail
Gobo Reset Fail
R-Gobo Reset Fail
Effect Reset Fail
R-Effect Reset Fail
Frost Reset Fail
Indicated moving part failed going to home
position after power up or fixture reset
· Check part’s free movement and integrity
· Check sensors’ wiring and position
· Check stepper motor, belt, and driver board
· Check the corresponding control board
· Check main control board