Chauvet 300E Smoke Alarm User Manual


 
Setup
-6- Legend 300E Spot User Manual Rev. 01g
3. Setup
AC Power
The Legend 300E Spot has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
Make sure that you are connecting this product to the proper voltage, as per the
specifications in this guide, the product’s user manual, or on the product’s sticker.
Always connect the Legend 300E Spot to a protected circuit with an appropriate
electrical ground to avoid the risk of electrocution or fire.
To determine the power requirements for the Legend 300E Spot
see the label affixed to
the side of the fixture. Alternatively, you may refer to the corresponding
specifications
chart in the Technical Information chapter of this manual.
The listed current rating indicates the maximum current draw during normal operation.
Please refer to the Sizing the Circuit Breakers section in the Appendix chapter of this
manual.
Never connect the Legend 300E Spot to a rheostat (variable resistor) or dimmer
circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The Legend 300E Spot comes with a bare ended power input cord. The fixture side of
this power cord enters the fixture through a strain reliever (rubber boot) and it cannot be
disconnected from the fixture. Use the table below to wire the plug to the power cord.
Connection Wire (US) Wire (Europe) Screw Color
AC Live Black Brown Yellow or Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green
Make sure to disconnect the fixture’s power cord before replacing a blown fuse,
and always replace it with a fuse of the same type and rating.
Fuse Replacement
1) With a Philips screwdriver, unscrew the fuse holder out of its housing and remove
the blown fuse from its holder.
2) Replace the blown fuse with a fuse of the exact same type and rating.
3) Reverse step 1 and reconnect power.
DMX Linking
You may link the Legend 300E Spot to a DMX controller using a standard DMX serial
connection. If using other DMX compatible fixtures with the Legend 300E Spot, it is
possible to control them individually with a single DMX controller.
If you are not familiar with the DMX standard, you may download the “DMX Primer”
document from the CHAUVET® Web site.
DMX Modes
The Legend 300E Spot uses the standard DMX data connection for its DMX Modes
(Mode 1 and Mode 2). You will find information about these DMX modes in the
Introduction chapter (brief description), the Operation Instructions chapter (configuration
details), and the DMX Values section (individual channel values)