Arena Hazer™ 2 User Manual 11 4/20/2010 4:23 PM
LED Indicators
When the fluid is low in the hazer, the low fluid indicator (shown as NO FLUID on the hazer) will light solid.
When the hazer detects DMX signal, the DMX indicator (shown as DMX OK on the hazer) will light solid.
Auto Cut-Off Feature
This product has a safety feature to keep the machine from becoming damaged. This is referring to the operation of the
pump. When the fluid tank is empty, the pump will still operate for a short time until all of the fluid has been removed from
the system. Then, it will sense that there is no fluid and will automatically stop the haze output. An indication that this has
occurred is when the LOW FLUID LED is lit and the tank LED is flashing blue.
It will take approximately 30 seconds to 1 minute for this feature to engage once the fluid has
emptied from the tank.
In order for the hazer to automatically reset, the trigger must be released. This may be from
the wired remote, or via a DMX controller. If it is via a DMX controller, then the DMX channel
will have to be brought to a value of 000 (0%) in order to allow the hazer to reset itself.
Once the tank has been refilled with fog fluid, you may resume using the hazer. The auto cut-
off will automatically reset.
The auto cut-off feature will not function if the wired remote is set to a haze output level less
than 3 or if the DMX value (In DMX mode) is set below 080.
Do not run the hazer without fluid. Failure to follow these instructions may void the warranty.
When the tank is empty, the LEDs will flash blue to indicate the auto cut-off feature has been
activated.