Chamberlain MR850 Garage Door Opener User Manual


 
OPERATION OF YOUR OPENER
Your opener can be activated by any of the following
devices:
The ACTIVATION button
Press the button until door starts to move.
The wall control, outside keyswitch or keyless
entry system (if you have installed any of these
accessories).
The Transmitter or Wireless Wall
Control (CM128)
Hold the push button down until the door starts to move.
When the opener is activated by transmitter,
ACTIVATION button or wall control:
If open, the door will close. If closed, the door will open.
If closing, the door will stop.
If opening, the door will stop (allowing space for entry
and exit of pets and for fresh air).
If the door has been stopped in a partially open or
closed position, it will reverse direction.
Obstruction behaviour:
If an obstruction is encountered while closing, the door
will reverse.
If an obstruction is encountered while opening, the door
will reverse and stop.
The optional Protector System™ uses an invisible beam
which, when broken by an obstruction, causes a closing
door to open and prevents an open door from closing. It
is STRONGLY RECOMMENDED for homeowners with
young children.
Opening the door manually:
The door can be opened manually by pulling the
release cord down firmly.
To re-engage the door, pull the release cord down firmly.
The opener light will turn on:
when opener is initially plugged in;
when the power is briefly interrupted;
when the opener is activated.
(the light turns off automatically after 2-1/2 minutes.)
MAINTENANCE OF YOUR OPENER
Once a Month:
Repeat safety reverse test.
Make any necessary adjustments
(sections 13 & 14).
Manually operate door. If it is unbalanced or
binding, call for professional garage door
service.
Check to be sure door opens and closes fully.
SPECIAL NOTE: Chamberlain strongly recommends that the Protector System
TM
be installed on all garage door openers.
CARE OF YOUR OPENER
When properly installed, your opener will operate
with minimal maintenance. The opener does not
r
equire additional lubrication.
Limit and Force Settings: These settings must be
checked and properly set when the opener is
installed. Weather conditions may cause some
m
inor changes in the door operation, requiring
some re-adjustments, particularly during the first
year of operation. Refer to limit and force setting in,
sections 13 & 14.
F
ollow the instructions carefully and repeat the
safety reverse test after any adjustment.
Transmitter: Additional transmitters can be
purchased at any time. Refer to Accessories. Any
new transmitters must be programmed into the
opener.
Transmitter battery: If transmission range
decreases, replace the battery.
SPECIFICATIONS MR850
Input Voltage: 230-240VAC, 50Hz, 170W
Rated Load: 32Nm
Max.Pull Force: 550N @ O300mm
Idle Current: less than 25mA @ 230VAC
Drive: 24volt DC gearmotor
permanent lubrication
Max. Drum Rotations: 4
1/
2
Memory Registers: 64
Operating Frequency: 433.92MHz
17
Door should be fully closed if possible.
Weak or broken springs could allow an
open door to fall rapidly. Property damage
or serious personal injury could result.
SPECIFICATIONS MR650
Input Voltage: 230-240VAC, 50Hz, 100W
Rated Load: 25Nm
Max.Pull Force: 500N @ O300mm
Idle Current: less than 25mA @ 230VAC
Drive: 24volt DC gearmotor
permanent lubrication
Max. Drum Rotations: 4
1/
2
Memory Registers: 64
Operating Frequency: 433.92MHz