Chamberlain ATS 2113X Garage Door Opener User Manual


 
17
Hex Bolt
1/4-20 x 1-1/2"
"C" Wrap
Sensor
with Wire
Wing
Nut
Indicator
Light
Figure 6
Invisible Light Beam
Protection Area
Safety Reversing
Sensor
Safety Reversing
Sensor
Connect Wire to
Opener Terminals
Bell Wire
Bell Wire
Finished
Ceiling
Sensor
Connections
Wall Control
Connections
(dotted line)
OPENER TERMINAL SCREWS
1
2
3
Figure 7
MOUNTING AND WIRING THE SAFETY SENSORS
Center each sensor unit in a “C” wrap with lenses pointing
toward each other across the door (see Figure 6).
Secure sensors with the hardware shown. Finger tighten the
wing nut on the receiving eye to allow for final adjustment.
Securely tighten the sending eye wing nut.
Run the wires from both sensors to the opener (see Figure 7).
Use insulated staples to secure the wire to wall and ceiling.
Strip 1/4" (6 mm) of insulation from each set of wires. Separate
white and white/black wires sufficiently to connect to the
opener terminal screws: white to 2 and white/black to 3.
ALIGNING THE SAFETY SENSORS
Plug in the opener. The indicator lights in both the sending
and receiving eyes will glow steadily if wiring connections and
alignment are correct.
The sending eye indicator light will glow regardless of alignment
or obstruction. If the indicator light in the receiving eye is off, dim,
or flickering (and the invisible light beam path is not obstructed),
alignment is required.
Loosen the sending eye wing nut and readjust, aiming directly
at the receiving eye. Lock in place.
Loosen the receiving eye wing nut and adjust sensor until it
receives the sender’s beam. When the green indicator light
glows steadily, tighten the wing nut.
TROUBLESHOOTING THE SAFETY SENSORS
If the 1. sending eye indicator light does not glow steadily after
installation, check for:
Electric power to the opener.
A short in the white or white/black wires. These can occur at
staples, or at opener connections.
Incorrect wiring between sensors and opener.
A broken wire.
If the 2. sending eye indicator light glows steadily but the
receiving eye indicator light doesn't:
Check alignment.
Check for an open wire to the receiving eye.
If the 3. receiving eye indicator light is dim, realign either sensor.
NOTE: When the invisible beam path is obstructed or misaligned
while the door is closing, the door will reverse. If the door is
already open, it will not close. The opener lights will blink 10
times. (If bulbs are not installed, 10 clicks can be heard.) See
page 15.