Chamberlain 6200-2K Garage Door Opener User Manual


 
To reduce the risk of electric shock, your garage
door opener has a grounding type plug with a third
grounding pin. This plug will
only
fit into a grounding
type outlet.
If the plug doesn't fit into the outlet you have,
contact a qualified electrician to install the proper
outlet.
Right
Wrong
Ground Tab
Green Ground
Screw
Ground Wire
Black
Wire
STEP 8 Connect Electric Power - Sears 315-699 #2
Model5315, 53415, 53515,43625 & 53699 (Yellow Disk #2)
3/3/89 - 7/25/89 - 8/2/89 - 4/17/92
Permanent wiring
connection
White Wire
Black
Wire
Installation Step 9
Electrical Requirements
Right
Wrong
Ground Tab
Green Ground
Screw
Ground Wire
Black
Wire
STEP 8 Connect Electric Power - Sears 315-699 #2
Model5315, 53415, 53515,43625 & 53699 (Yellow Disk #2)
3/3/89 - 7/25/89 - 8/2/89 - 4/17/92
Permanent wiring
connection
White Wire
Black
Wire
To make a permanent connection through the 7/8"
diameter hole in the top of the opener (according to
local code):
• Remove the opener cover screws and set the
cover aside.
• Remove the attached 3-prong cord.
• Connect the black (line) wire to the screw on the
brass terminal; the white (neutral) wire to the
screw on the silver terminal; and the ground wire
to the green ground screw.
The opener must be
grounded.
• Reinstall the cover.
20
To prevent electrocution or fire,
installation
and wiring must be in compliance with local
electrical and building codes.
Do
NOT
use an extension cord, 2-wire adapter,
or change the plug in any way to make it fit
your outlet.
To avoid installation difficulties,
do not run the opener at this time.
To avoid installation difficulties,
do not run the opener at this time.
If permanent wiring is required by your local code, refer to the following procedure:
To prevent electrocution, remove power from
the garage door opener
and
from the circuit
you plan to use for the permanent connection.
WARNING
CAUTION
WARNING
WARNING
CAUTION
WARNING