Chamberlain 3280M-267 Garage Door Opener User Manual


 
13
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
Be sure power is not connected BEFORE installing door
control.
Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
Install door control within sight of garage door, out of reach
of children at a minimum height of 5 feet
(1.5 m), and away from all moving parts of door.
NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door at a minimum
height of 5 feet (1.5 m) where small children cannot reach,
and away from moving parts of door and door hardware.
The installation surface must be smooth and flat. If
installing into drywall (Figure 1), drill 5/32" holes and use
anchors provided. For pre-wired installations (as in new
home construction), it may be mounted to a single gang
box (Figure 2). NOTE: After installation, a green or amber
indicator light behind the cover will indicate proper
connection. If not lit, the Lock and Light features will not
function (reverse wires to correct).
1. Strip 7/16" (11 mm) of insulation from one end of bell
wire and connect to the two screw terminals on back of
door control by color: white wire to WHT and white/red
wire to the RED (Figure 3).
2. Remove cover by gently prying at slot in the top of the
cover with a small flat head screwdriver (Figure 4).
Fasten with 6ABx1-1/4" self-tapping screws (drywall
installation) or 6-32x1" machine screws (into gang box)
as follows:
Drill and install bottom screw, allowing 1/8"
(3 mm) to protrude above wall surface.
Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
Install top screw with care to avoid cracking plastic
housing. Do not overtighten.
Insert bottom tabs and snap on cover.
NOTE: The push bar may stick if the door control is not
mounted on a smooth surface. If a click is not heard
when pressing the push bar, loosen the two mounting
screws or relocate the door control to a smoother
surface.
3. (Standard installation only) Run bell wire up wall and
across ceiling to motor unit. Use insulated staples to
secure wire in several places. Do not pierce wire with a
staple, creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red (Figure 5).
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.
5. Use tacks or staples to permanently attach entrapment
warning label to wall near door control, and manual
release/safety reverse test label in a prominent location
on inside of garage door.
NOTE: DO NOT connect power and operate opener at this
time. The trolley will travel to the full open position but will
not return to the close position until the sensor beam is
connected and properly aligned.
To release or insert wire,
push in tab with screwdriver tip
Door Control
Connections
7/16" (11 mm)
Strip wire 7/16" (11 mm)
Red
Grey
White
LOCK
LIGHT
Figure 4
REMOVE COVER
Bell Wire
Terminal
Screws
Bottom Mounting Hole
Top Mounting Hole
Drywall Anchors
Insulated
Staples
Screw 6ABx1-1/4"
(standard installation)
Screw 6-32x1"
(pre-wired)
HARDWARE SHOWN ACTUAL SIZE
Figure 2
To Replace
Insert Bottom Tabs First
PRE-WIRED
INSTALLATION
LOCK
LIGHT
LOCK
LIGHT
To Replace
Insert Bottom Tabs First
Figure 1
STANDARD
INSTALLATION
24 Volt
2-Conductor
Bell Wire in
Gang Box
Figure 5
Figure 3
MULTI-FUNCTION
DOOR CONTROL (BACK)
KG
1
3
9
7
5
KG
1
3
9
7
5