Chamberlain 248730 Garage Door Opener User Manual


 
23
ADJUSTMENT STEP 3
TEST THE SAFETY REVERSAL SYSTEM
Test
With the door fully open, place a 1-1/2" (3.8 cm) board
(or a 2x4 laid fl at) on the fl oor, centered under the
garage door.
Operate the door in the down direction. The door must
reverse on striking the obstruction.
Adjust
If the door stops on the obstruction, it is not traveling
far enough in the down direction. Increase the down
travel by turning the DOWN limit adjustment screw
counterclockwise 1/4 turn.
NOTE: On a sectional door, make sure limit adjustments
do not force the door arm beyond a straight up and
down position. See page 14.
Repeat the test.
When the door reverses on the 1-1/2" (3.8 cm) (or a
2x4 laid fl at) board, remove the obstruction and run
the opener through 3 or 4 complete travel cycles to test
adjustment.
TEST THE PROTECTOR SYSTEM
®
Press the remote control push button to open the door.
Place the opener carton in the path of the door.
Press the remote control push button to close the door.
The door will not move more than an inch, and the
opener lights will fl ash.
The garage door opener will not close from a remote if the
indicator light in either sensor is off (alerting you to the
fact that the sensor is misaligned or obstructed).
If the opener closes the door when the safety reversing
sensor is obstructed (and the sensors are no more than
6" (25 mm) above the fl oor), call for a trained door
systems technician.
Without a properly installed safety reversing sensor,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing
garage door.
• Safety reversal system MUST be tested every month.
• If one control (force or travel limits) is adjusted, the
other control may also need adjustment.
• After ANY adjustments are made, the safety reversal
system MUST be tested. Door MUST reverse on
contact with 1-1/2" (3.8 cm) high object (or 2x4 laid
fl at) on the fl oor.
1-1/2" (3.8 cm) board (or a 2x4 laid fl at)
Safety Reversing SensorSafety Reversing Sensor