Vermont Casting SR36A Indoor Fireplace User Manual


 
15
SR/SC Series "A" Woodburning Fireplace
7412948
MA81
rev. 8/5/97
1"
Ref.
Combustible materials are
permitted within a shaded area
shown in Figure 23 titled
Minimum Wall Clearances.
*
**
MA81
Fig. 22 Combustible mantle clearances.
*12" from top of fireplace opening for radi-
ant models
12" from top of grille opening for circulating
models
**6" from top of fireplace opening for radi-
ant models (Noncombustible material must
separate the black face surround of the fire-
place and any combustible mantel material)
6" from top of grille opening for circulating
models
Face Plate
12"
(305mm)
Max.
FP531a
BR/BC
mantel clearances
9/03 djt
1/2"
12"
(305mm)
Max.
12"
(305mm)
Min.
1"
(38mm)
*
12"
(305mm)
Min.
1"
(38mm)
6"
(159mm)
Min.
12"
(305mm)
Max.
12"
(305mm)
Min.
1"
(38mm)
6"
(159mm)
Min.
Mantel Clearance - Radiant
Model - No Noncombustible
Facing Material
Combustible
Mantel and
Trim
Finished Wall
Header
Standoff
Noncombustible
Material
Radiant Sur-
round Face
Fireplace Open-
ing
* Minimum width from top of sur-
round to bottom of screen rail
Combustible Man-
tel and Trim
Mantel Clearance - Radiant Model
- with Noncombustible Facing
Material
Header
Standoff
Noncombustible
Material
Finished Wall
Noncombustible Fac-
ing Material
Radiant
Surround
Face
Fireplace Open-
ing
Mantel Clearance -
Circulating Model
Combustible Man-
tel and Trim
Header
Standoff
Noncombustible
Material
Finished Wall
Circulating
Front
Fireplace
Opening
2 x 4 Stud
Finished Wall
Must be sealed with
Noncombustible
Material
Fireplace
Front
Fig. 21 Mantel clearances.
Top View
FP531a