Vermont Casting SNV30 Electric Heater User Manual


 
13
Stardance Natural Vent Gas Heater
20007067
Fig. 22 To open the front doors, turn handle clockwise.
ST261
Stardance
operable doors
1/31/01
Clockwise
to Open
Counterclockwise
to Close
ST624
The Stardance is operated with the operable door front
plate in place with the doors open or closed. To open
the front doors, insert the handle into the door latch
stub and turn it to the left and up. (Fig. 22) When not in
use, the handle may be stored in the handle holder on
the right side of the rear shroud. (Fig. 23)
Operation
Your First Fire
Read these instructions carefully and familiarize
yourself with the burner controls shown in Figure 27.
Locate the pilot assembly, Figure 24. Follow the lighting
instructions on Page 14 exactly.
During the first fire, it is not unusual to smell some
odor associated with new logs, paint and metal being
heated. Odors should dissipate within an hour or so,
however, you can open a window to provide fresh air to
alleviate the condition.
Pilot and Burner Inspection
Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in Figure
26. If flame patterns are incorrect, turn the heater off.
Contact your dealer or a qualified gas technician for as-
sistance. Do not operate the heater until the pilot flame
is correct.
Follow regular maintenance procedures as described
on Page 19.
ST624
handle holder
2/6/01
Handle
Holder
ST624
Fig. 23 When not in use, store handle in the handle holder.
ST477
Stardance
pilot location
10/4/00
Fig. 24 Pilot Assembly location.
ST476
Pilot As-
sembly
Flame & Temperature Adjustment
For stoves equipped with HI/LO valves, flame adjust-
ment is accomplished by rotating the HI/LO adjustment
knob located near the center of the gas control valve.
(Fig. 25)
Flame Characteristics
It is important to periodically perform a visual check
of the pilot and the burner flames. Compare them to
Figure 26. If any of the flames appear abnormal, call a
service person.


Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
HV102
Honeywell hi/lo knob
4/5/99 djt
Fig. 25 Flame adjustment knob for Honeywell valve.
CO105c
Pilot flame
4/10/00 djt
LG143
Fig. 26 Correct pilot and burner flame pattern.
LG142
Stardance
Install logs 2
12/11/00 djt
Red Glow
CO105c