Vermont Casting SDDVTCVG Gas Heater User Manual


 
7
Stardance Direct Vent/Natural Vent Gas Heater
20012734
ST128b
Stardance
flue centerline
9/28/00 djt
C
L
C
L
B
D
C
A
Parallel Installation: Minimum Clearance
and Flue Centerline, Direct Vent and
Natural Vent
ST128b
Stove Clearances: A: 4” (102 mm)
B: 4” (102 mm)
Pipe Centerlines: C: 15¹⁄₂” (395 mm)
D: 9” (229 mm)
Fig. 3 Parallel installation, minimum back and side clear-
ances, and flue centerlines.
Corner Installation:
Minimum Clearance and Flue Centerline,
Direct Vent and Natural Vent
ST129b
Stardance
corner specs
9/28/00 djt
A
A
B
B
Stove Clearance: A: 4” (102 mm)
Pipe Centerline: B: 14¹⁄₂” (370 mm)
ST129b
Fig. 4 Corner installation, minimum corner clearance and flue
centerline.
Wall Centerline from Floor
ST131b
Stardance
wall thimble
9/28/00 djt
A
Direct Vent Only
ST131b
Effective Minimum
Wall Thimble 56” (1480 mm) (CFM Pipe)
Centerline 52” (1378 mm) (Simpson Duravent Pipe)
Fig. 5 Minimum wall thimble centerline.
Wall and Ceiling Clearances
A
C
D
ST101b
Stardance
Direct Vent
Min. Clrnc
9/28/00 djt
B
ST101b
A: Rear Wall 4” (102 mm)
B: Min. Clearance 45¹⁄₄” (1154 mm)*
C: Min. Alcove Height 72” (1830 mm)
D: Max. Alcove Depth 48” (1220 mm)
Sidewall Clearance 4” (102 mm)
Fig. 6 Dimensions and clearances to ceiling or alcove.
Hearth Requirements
The Stardance Heater must be installed on rigid floor
-
ing. When the heater is installed directly on any com-
bustible surface other than wood flooring, a metal or
wood panel extending the full width and depth of the
unit must be used as the hearth. There are no other
hearth requirements.