Vermont Casting SDDVRVG Gas Heater User Manual


 
37
Stardance Direct Vent - Rear Vent Gas Heaters
20012950
Comfort Valve System Control Sequence Of Operation With Transmitter
Set manual switch
to local or remote
five minute wait
period
Light pilot burner
Did the LED stop
blinking?
Review LED
failure analysis
Release pilotstat
knob
Turn pilotstat knob
from PILOT to ON
Cycle switch once
and leave in remote.
Pressy any key on
transmitter for
recognition operation
Choose Manual or
Remote path. Set
switch to manual or
remote.
Yes
Local Path
If manual switch is
set to LOCAL, did
main burner light and
fan turn on?
Move switch from
local to remote.
Press any key on
transmitter. Move
switch back to
local.
Turn pilotstat knob
to PILOT to turn off
main burner.
Turn pilotstat knob
to OFF to turn valve
completely off.
Yes
If the manual switch
is set to REMOTE,
press the mode but-
ton to display “ON”.
Does transmitter con-
trol the main burner
and fan?
Move switch from
manual to remote.
Press any key on
transmitter.
Does transmitter
change levels of flame
height, fan speed?
Set levels of flame
height and fan to “0:
to shut off main burner
and fan.
Turn pilotstat knob
to OFF to turn valve
completely off.
Yes
No
On Path