Vermont Casting RUVS40 Electric Heater User Manual


 
8
Vermont Castings Radiance
A: Maximum Alcove Depth.............. 24" (609mm)
B: To Side Wall................................... 4" (101mm)
C: To Rear Wall ................................. 4" (101mm)
D: To Ceiling................................... 60" (1524mm)
The Radiance Unvented heater may be installed in an
alcove constructed to maintain the clearances speci-
fied below.
Alcove Clearances
Hearth Requirements
The Radiance Unvented heater must be installed on
rigid flooring. If the appliance is installed on any
combustible surface other than wood flooring, such as
carpet or tile, a metal or wood panel must be installed
to extend the full length and width of the unit. There
are no other hearth or floor protection requirements.
• Do not install this heater in a bathroom or
bedroom.
• Installation of this heater must conform with
local codes or, in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.1.
• This heater creates warm air currents. These
currents move heat to wall surfaces next to the
heater. Installing the heater next to vinyl or cloth
wall coverings or operating the heater where
impurities in the air such as tobacco smoke exist,
may discolor walls.
Do not use a blower insert, heat exchanger
insert or other accessory not approved for use
with this heater.
A: Maximum Mantel Depth .............. 7¹⁄₂" (190.5mm)
B: To Side Wall / Trim* ........................ 4" (101.6mm)
C: To Rear Wall ...................................4" (101.6mm)
D: To Mantel / Trim* ... 16" (406.4mm) / 2" (50.8mm)
* Trim is 1" thick max.
A = Depth, Mantel and/or Top Trim
B = Height from top of heater
C = Min. 10"
When:
A = 7¹⁄₂" (190mm) max. A = 3” (75mm) max.
B = 16" (406mm) min. B = 11¹⁄₂" (292mm) min.
A = 6" (152mm) max. A = 1¹⁄₂" (38mm) max.
B = 14¹⁄₂" (368mm) min. B = 10" (254mm) min.
A = 4¹⁄₂" (114mm) max.
B = 13" (330mm) min.
Fig. 5 Freestanding Clearances.
Fig. 7 Alcove Clearances.
Clearance Requirements
Minimum Clearances to Combustible
Materials
Maintain clearance, (empty space), between combus-
tible materials and the heater as specified below.
Freestanding Stove
WARNING
Fig. 6 Mantel Clearances.
A
B
C
D
D
A
BB
C
ST101
ST103a
ST185
A
B
C