Vermont Casting DVT38 Indoor Fireplace User Manual


 
30
Chateau™
20011956
Lighting & Operating Instructions
For Fireplaces equipped with American Flame Automatic Control System (IN or IP)
A. This fireplace is equipped with an ignition device
which automatically lights the pilot and main burner.
The pilot and burner light automatically with the hand
held remote control only. DO NOT try to light the
pilot by hand. Before lighting this appliance, follow
these instructions exactly.
B. BEFORE OPERATING, smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than the air
and will settle on the floor.
What to do if you smell gas
Do not try to light any appliance.
For Your Safety, Read the Following Warnings
before Lighting the Appliance
Do not operate any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppliers
instructions.
If you cannot contact your gas supplier call the
Fire Department
C. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and replace any part of the
control system and any gas control that has been
under water.
1. Turn the wireless remote to the OFF position.
2. Turn OFF all electrical power to the fireplace if
service is required.
3. Turn the shut-off valve on the gas supply line to
the OFF position.
FP297A
Warning: If you do not follow these instructions exactly, a fire or explosion may
result, causing property damage, personal injury and loss of life.
Lighting Instructions
Turning Off the Gas to the Appliance
1. STOP! Read the safety information above before
continuing.
2. Turn off all electrical power to the appliance.
3. This appliance is equipped with an ignition device
which automatically lights the pilot. DO NOT try to
light the pilot by hand.
4. Turn the wireless remote OFF.
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP. Follow instruction B
in the safety warnings above. If you do not
smell gas, go on to the next step.
6. Turn ON all electrical power to the
appliance.
7. Turn wireless remote ON.
9. If the appliance will not operate, follow the
instructions TURNING OFF THE GAS TO
THE APPLIANCE, and call your service
technician or gas supplier.
FP297A
INSTA VENT FREE
UVHB26 GAS SUPPLY
7/1/98
1/2” Gas Supply
1/2” NPT X 1/2” Flare
Shut-off Valve
1/2” Gas Tight or
Tinned Copper
(from valve)
(Not provided)



“S” Connection
Connect to Module
Spark to Pilot
Pilot Assembly
Pilot Gas
Connection Side or Back
“I” Connection
Connect to
Module
Main Valve Internal Solenoid
Connection
Green & White Wires
Pilot Internal Solenoid
Connection
Orange & White Wires
Pilot
Adjustment
Screw
Motor Wires
Black Plastic Cap
Minimum Rate
Screw
Motor Drive