Vermont Casting DVRT39 Indoor Fireplace User Manual


 
11
10002428
Vermont Castings, Majestic Products DVRT36/39/43
General Venting
Your fireplace is approved to be vented either through
the side wall, or vertically through the roof.
NOTE: Only venting components specifically
approved and labeled for this fireplace may be
used.
Venting terminals shall not be recessed into a wall
or siding.
Horizontal venting must be installed on a level plane
without any incline or decline.
There must not be any obstructions such as
bushes, garden sheds, fences, decks, or utility
buildings within 24” (610mm) from the front of the
termination hood.
Do not locate the termination hood where excessive
snow or ice buildup may occur.
Be sure to check and clear the vent termination
area after snow falls, to prevent accidental blockage
of venting system.
When using snow blowers, make sure snow is not
directed toward the vent termination area.
Location of Vent Termination
It is imperative to observe minimum
clearances (shown on the following
page) when locating vent terminations.