Vermont Casting CR36L Indoor Fireplace User Manual


 
5
CR Series Woodburning Fireplaces
20001316
0 0 0 0 0 3” 11”
1 0 0 0 0 8¹⁄₄" 20"
0 1 0 0 0 11
¹⁄₄" 25¹⁄₄"
2 0 0 0 0 13
¹⁄₂" 29¹⁄₄"
1 1 0 0 0 16¹⁄₂" 34¹⁄₄"
0 0 1 0 0 20
¹⁄₄" 40³⁄₄"
2 1 0 0 0 21
³⁄₄" 43¹⁄₂"
0 0 0 1 0 26¹⁄₄" 51¹⁄₄"
0 1 1 0 0 28¹⁄₂" 55¹⁄₄"
1 0 0 1 0 31
¹⁄₂" 60¹⁄₄
0 1 0 1 0 34
¹⁄₂" 65¹⁄₂"
0 0 2 0 0 37¹⁄₂" 70³⁄₄"
1 1 0 1 1 41
¹⁄₂" 77³⁄₄"
0 0 1 1 1 45" 83
³⁄₄"
0 1 2 0 1 47
¹⁄₄" 87¹⁄₂"
0 0 0 2 1 51" 94"
0 1 1 1 1 53
¹⁄₄" 98"
0 0 3 0 1 56
¹⁄₄" 103¹⁄₄"
0 1 0 2 1 59¹⁄₄" 108¹⁄₂"
0 0 2 1 1 62¹⁄₄" 113¹⁄₂"
0 1 3 0 1 64
¹⁄₂" 117¹⁄₂"
0 0 1 2 1 68
¹⁄₄" 124"
0 1 2 1 1 70¹⁄₂" 128"
0 0 0 3 1 74
¹⁄₄" 134¹⁄₂"
0 1 1 2 2 78" 140
³⁄₄"
0 0 3 1 2 81" 146"
0 1 0 3 2 84" 151¹⁄₄"
0 0 2 2 2 87" 156
¹⁄₂"
0 1 3 1 2 89
¹⁄₄" 160¹⁄₄"
0 0 1 3 2 93" 166³⁄₄"
0 1 2 2 2 95
¹⁄₄" 170³⁄₄"
0 0 0 4 2 99
¹⁄₄" 177³⁄₄"
0 1 1 3 2 101¹⁄₄" 181³⁄₄"
0 0 3 2 2 104¹⁄₄" 186¹⁄₄"
0 1 0 4 2 107
¹⁄₄" 191¹⁄₂"
0 0 2 3 2 110
¹⁄₄" 196³⁄₄"
0 1 3 2 3 114" 203¹⁄₄"
0 0 1 4 3 117
³⁄₄" 209³⁄₄"
0 1 2 3 3 120" 213
¹⁄₂"
0 0 0 5 3 123
³⁄₄" 220"
D
B
G
H
B
C
E
6 FT.
G
H
A
FP269CR
CR Series
2/19/99 djt
30˚ Elbow Offsets
1’
1¹⁄₂'
3’ 4’
Offset
Rise
Chimney
Support
Illustration Key
The following safety rules apply to offset
installations. (The letters correspond with
letters above):
A. Height of the chimney measured from
the hearth to the chimney exit at top:
CR36L/R Series
Maximum: 90’0”
Minimum:
Without elbows 14’ 0”
With 2 elbows 15’ 0”
With 4 elbows 21’ 0”
B. Do not use more than four elbows per
chimney.
Attach the straps of the top elbows to a
structural framing member.
The first elbow of any pair does not have
straps.
C. The chimney cannot be more than 30°
from the vertical plane.
D. The maximum length of the angled run
of the total chimney system is 20 feet. (G
plus H cannot exceed 20 feet)
E. A chimney support (Model SKCS8) is
required every 6 feet of angled run of
chimney. Chimney supports are required
at 30 feet and 60 feet of chimney height
above the hearth also.
Determine the offset distance of your chim
-
ney arrangement from the centerline of the
fireplace to the centerline of the chimney
where it is to pass through the first ceiling.
NOTE: This offset distance may not be your
full offset distance. See Examples 2 and 3.
Chimney Flue Exit
Chimney
Section
Elbow
Rise
Offset
Hearth Floor
Example 1 Example 2 Example 3
30°
Offset
Elbow
30°
Offset
Elbow
30°
Return
Elbow
30°
Return
Elbow
SKCS8
Support
NOTE: G + H Cannot Exceed 20’
Fig. 3 Chimney system requirements.
FP269CR
Chimney Requirements - Offset Installations
IWF282
MBUF
5/26/96
OFFSET
RISE
FP282