Vermont Casting 3360 Indoor Fireplace User Manual


 
23
Radiance Direct Vent /Natural Vent Gas Heater
20004188
The Radiance is shipped with the operable door front
plate. The stove may be operated with the doors either
open or closed. To open the front doors, insert the
handle into the door latch stub and turn it to the right
and up. (Fig. 44) When not in use, the handle may be
stored in the handle holder on the right side of the rear
shroud. (Fig. 45)
Operation
Your First Fire
Read these instructions carefully and familiarize
yourself with the burner controls shown on Page 24.
Locate the pilot assembly, Figure 46. Follow the lighting
instructions on Page 24 exactly.
During the first fire, it is not unusual to smell some
odor associated with new logs, paint and metal being
heated. Odors should dissipate within the first eight to
ten hours, however, you can open a window to provide
fresh air to alleviate the condition.
Pilot and Burner Inspection
Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in Figure
48. If flame patterns are incorrect, turn the heater off.
Contact your dealer or a qualified gas technician for as-
sistance. Do not operate the heater until the pilot flame
is correct.
Follow regular maintenance procedures as described
on Page 32.
ST624
handle holder
2/6/01
RADIANCE
Handle
Holder
ST656
Fig. 45 When not in use, store handle in the handle holder.
ST477
Stardance
pilot location
10/4/00
Fig. 46 Pilot Assembly location.
ST476
Pilot As-
sembly
ST621
Stardance
operable doors
1/31/01
Fig. 44 To open the front doors, turn handle counterclockwise.
Clockwise
to Close
Counterclockwise
to Open
ST621
Flame & Temperature Adjustment
For stoves equipped with HI/LO valves, flame adjust-
ment is accomplished by rotating the HI/LO adjustment
knob located near the center of the gas control valve.
(Fig. 47)


Turn
counterclockwise
to decrease
flame height
Turn clockwise
to increase
flame height
HV102
Honeywell hi/lo knob
4/5/99 djt
Fig. 47 Flame adjustment knob for Honeywell valve.
Flame Characteristics
It is important to periodically perform a visual check
of the pilot and the burner flames. Compare them to
Figure 48. If any of the flames appear abnormal, call a
service person.
Fig. 48 Correct pilot and burner flame patterns.
LG157
Radiance logs
flame
4/24/01 djt
Red Glow
LG157
CO105c
Pilot flame
4/10/00 djt
CO105c
PSE
Pilot
SIT Pilot