Vermont Casting 2950 Fan User Manual


 
24
Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters
20003457
26"
(660mm)
16"
(406mm)
ST379a
Transition
Connector
Fig. 45 SDVR minimum lintel height for flush or forward placement.
26"
(660mm)
20¹⁄₂"
(521mm)
ST380a
Transition
Connector
Fireplace Installation Requirements - SDVR
6"
(152mm)
20¹⁄₂"
(521mm)
26"
(660mm)
*
Existing Wood Stove
Chimney Pipe
Finished
Combustible Wall
ST713a
* Transition pipe must be at least 6”
(152mm) from any combustible material.
Fig. 46 SDVR installations using existing wood stove chimney pipe.
X
Existing Vent Pipe
Transition Connector
Field
Fabricated Cover
ST714
“X” must be 6” (151mm) from any combustible material
unless completely covered by field fabricated sheet metal. If
3” vent pipes are covered by sheet metal, the clearance to
combustibles may be 2” (51mm).
Fireplace Installations Using Existing Wood Stove Chimneys