14
Defiant 1610CE Non-Catalytic Woodburning Stove
30003846
The Defiant Controls
Two controls regulate the performance of the Defiant: a
primary air control supplies oxygen for the fire, and a
damper directs air flow within the stove to activate and
deactivate the catalytic combustor. (Fig. 25)
Symbols cast into the stove are reminders of the correct
directions for using the controls. The words ‘Left’ and
‘right’ in these directions are facing the stove.
Operation
ST541
Defiant
front view
controls
11/00
Griddle Handle
Door Handle
Air
Control
Lever
Ash Door Handle
ST541
Door Handle
Holder
(Behind
Leg)
Andiron
Damper
Handle
Fig. 25 The Defiant’s controls are conveniently located and
easy to operate.
A Single Air Control Regulates
Heat Output and Burn Time
The primary air control lever, on the right side of the
stove, controls the amount of incoming air for starting,
maintaining, and reviving a fire.
More air entering the stove makes the fire burn hotter
and faster, while less air prolongs the burn at a lower
heat output level. (Fig. 26)
For the greatest air supply and maximum heat output
(but the shortest burn time), move the lever toward the
front of the stove. For a fire that will last longer with
less heat, move the lever toward the rear of the stove.
A Damper Directs Air Flow
Within the Stove
The damper handle on the left side of the stove oper-
ates the damper to direct air flow within the stove.
The damper is open when the handle points to the
rear, enabling smoke to pass directly into the chimney.
The damper must be open when starting or reviving a
fire, and whenever the griddle or doors are opened.
The damper is closed when the handle points forward.
Smoke travels through the non-catalytic combustion
DEFIANT
DEFIANT
DEFIANT
ST541
thermostat
settings
11/00
Low Heat
Range
Air Control Positions
Medium Heat
Range
High Heat
Range
ST542
Fig. 26 The handle also may be positioned anywhere be-
tween the two extremes for different heat levels.
DEFIANT
DEFIANT
ST543
Damper
positions
11/00
Damper Positions
Open
(Updraft Mode)
Closed
(Efficient Mode)
ST543
Fig. 27 The Defiant’s damper operating positions.
Two Ways to Add Fuel
The Defiant’s griddle lifts for convenient top-loading of
logs, and is the easiest way to add fuel. (Fig. 28)
system where it can be further burned, before passing
up the chimney. (Fig. 27)
The damper should always be either fully open or
fully closed. There are no intermediate positions.
When closing the damper, be sure to pull firmly
enough to snap the handle into the locked posi-
tion.