Carrier 2020 Air Cleaner User Manual


 
5
Step 4 Wiring
a. Ensure power has been removed from the heating and
cooling system.
b. Turn the Infinityt Air Purifier power switch off.
c. Connect the power cord and the flow sensor cord to the
power supply connector and the flow sensor connector
(see Fig. 7 and Fig. 8).
NOTE: The power cord can be routed through the opposite side
of the cabinet. Zip ties have been enclosed to secure the power
cord to the side of the power supply.
NOTE: Cable connector and block--off plates will need to be
removed and re--installed if the power cord is re--routed. Screws
on the cable connector clamp should be tightened to 9 in. -- lbs.
torque.
NOTE: The Infinityt Air Purifier is to be powered by
208/230Vac/60 Hz.
NOTE: The Infinityt Air Purifier should only be powered
when airflow is present. An airflow sensor is factory--installed
(See Fig. 2 and Fig. 11). In order to bypass the airflow sensor,
use the special bypass jumper included in the parts bag. With the
bypass jumper in place, the air purifier will be on at all times
when connected to electrical line power (see Fig. 10).
d. Attach the quick connect terminals to the fused power
connector leads (in parts bag attached to power cord)a nd
connect to incoming field power. Attach the ground ring
to fan coil chassis ground. (See Fig. 10.)
ELECTRICAL SHOCK AND HIGH V OLTAGE
HAZARD
Failure to follow this w arning could result in personal injury
or death.
Before installing or servicing system, always turn off main
power to system. There may be more than 1 disconnect
switch.
!
WARNING
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage or improper operation.
This unit cannot be powered directly from blower motor
leads. Do not wire directly to blower motor. Wiring to
blower motor will damage power supply and void
warranty.
CAUTION
!
A06414
Fig. 7 --- Flow Sensor Cable Installed
A06413
Fig. 8 --- Power Cord Installed
AIR FLOW S ENSOR CABLE OR AIR FLOW
SENSOR BYPASS PLUG MUST BE CONNECTED
TOTHEPOWERSUPPLYINORDERTO
ACTIVATE THE AIR PURIFIER
NOTICE
A06670
Fig. 9 --- Airflow Sensor Bypass Plug Installed
GAPAB