Cadet EPA1000 Electric Heater User Manual


 
How Softheat hydronic baseboards work:
Inside a Softheat baseboard, a hermetically sealed water and
anti-freeze solution is heated by an electric heating ele-
ment. As the solution is heated, warmth is generated and
transmitted through dozens of aluminum fins along the
heater tube (it could initially take 30 to 60 minutes to warm a
room, depending on the room size). As the warmth spreads
outward from the heater, cooler air from the floor and wall nat-
urally flow toward the base of the heater. "Convection air heat-
ing" (See Figure 3) provides heat without fans, preventing the
heater from blowing or burning dust particles. The room is
warmed with even, comfortable heat without cold and hot
spots throughout the room. While Softheat offers everyone
a comfortably warm room, it was specifically designed to
reduce the effects of indoor allergens, compared to other
heating systems. Additional benefits include lower operat-
ing surface temperature and whisper quiet operation.
WARNING!
Element filled with
heat transfer fluid
containing 20%
Ethylene Glycol. In
the unlikely event of
leakage, if consumed,
call your local
poison control cen-
ter or seek medical
attention
immediately.
WARNING!
Risk of Fire. Heaters
must be kept clean
of lint, dirt and
debris.
Failure to follow
warnings may cause
heater to eject
sparks, ignite
materials, or cause
electrical shock.
Cold AirCold Air
Warm Air
Warm Air
Warm Air
Room Air
HEAT
LIMIT CONTROL
HEATING ELEMENTS
RED
RED
BLACK
RED
POLARIZED
BLADE PLUG
CLOSE L1
THERMOSTAT
WATTAGE SWITCH
RED
ON HEAT
LIMIT CONTROL
BLACK
WHITE
POLARIZED
BLADE PLUG
CLOSE L2
THERMOSTAT
OFF L1
WATTAGE SWITCH
HEATING ELEMENTS
Single Pole Thermostat
EPA750 and EPA1000 (120 Volt)
EPA1500/3 (120 Volt)
Model EPA750 EPA1000 EPA1500/3
BTUs
2560 3413 1707/3413/5120
Watts 750 1000 500/1000/1500
Volts (AC) 120 120 120
Phase 111
Hertz 60 60 60
Amps 6.3 8.3 4.2/8.3/12.5
Length* 47” 59” 71”
* Approximate Metric equivalents: 4' = 1,2m, 5' = 1,5m, 6' = 2m.
Operation Instructions
Figure 3.
HEATER MAINTENANCE
SOFTHEAT has no moving parts to wear
out, so it is virtually maintenance-free.
However, it is recommended to periodi-
cally remove the front cover (UNPLUG
UNIT FIRST) and vacuum the lint or
dust from the inside of the heater to
maintain peak heat transfer into the air.
Use caution when vacuuming to avoid
damaging the aluminum fins.
PILOT LIGHT
THERMOSTAT
LIMIT
HEATER TUBE
RED
RED
RED
BLACK
BLACK
RED
HEATER ELEMENT
POLARIZED
BLADE
PLUG
Double Pole Thermostat
EPA750 and EPA1000 (120 Volt)
Please note: If your heater has a thermostat control knob that is labeled with an “OFF” position, the unit
is equipped with a double pole thermostat. No heating will occur when the thermostat is rotated to the
full counterclockwise “OFF” position.